Continuous RF monitoring for labs, chambers and production lines
RF faults in a lab could go unnoticed until they show up in the data: A cable shield wears through, a connector works loose or a shielded enclosure stops sealing properly, and the first sign is a result that doesn’t make sense, sometimes after a run of tests that then has to be repeated.
The RadGreen RF & Microwave Monitoring System runs 24 hours a day at the point where a fault would show up: beside an ATE rack, outside a chamber, along a cable run. Each unit is band-selective across 100 MHz to 40 GHz and alerts as soon as the RF level rises above the threshold set for that location.

Alerting, not measurement
RadGreen is an alerting system. It is not a substitute for a spectrum analyser, EMI receiver or calibrated field probe, and it is not intended to produce compliance data. What it does is watch continuously, including the hours when nobody is measuring, and tell you when the RF environment changes.
That makes it a practical companion to measurement equipment. If you run radiated immunity tests with high-power RF amplifiers, a unit outside the chamber flags leakage while the test is running rather than after it. On a production line, a unit beside the test station picks up a failing cable or load before it affects a batch of results.
The units are maintenance-free and need no periodic calibration. Thresholds are set once for each installation.

What it picks up
- Damaged coaxial cable shielding. Worn, kinked or crushed cables leak RF into the surrounding area and raise the background level around the test set-up.
- Faulty coaxial connectors. A loose or degraded connector can leak intermittently, which is the kind of fault spot checks tend to miss.
- Broken dummy loads or antennas. A failed load radiates power it should be absorbing.
- Faraday cage and shielded enclosure leakage. Shielding can degrade between formal checks. A unit outside the enclosure flags a breach when it happens.
- RF rooms and anechoic chambers. Monitoring at the chamber picks up RF escaping during a test, so the problem is found while the test is still running.
- RF left on by mistake. A source energised by human error or a software fault is picked up straight away, rather than whenever someone notices.
Three ways to deploy
RadGreen RF units come in three types. Connected units suit labs and sites that want central oversight, while the Local unit works entirely on its own.
| Indoor Connected | Outdoor Connected | Local Visual and Voice | |
|---|---|---|---|
| Alerts | Notifications through the central platform | Notifications through the central platform | Visual and audible alerts on the device |
| Network connection | Required | Required | Not required |
| Data logging and remote configuration | Yes | Yes | Optional screen adds on-device display and settings |
| Multiple locations | Managed from one system | Managed from one system | Each unit operates independently |
| Typical use | Labs, test areas and production floors | Outdoor environments | Security-sensitive sites, including defence |
Local unit with optional screen
The Local Visual and Voice unit needs no communication network, which makes it suitable for sites where networked devices are not allowed. An optional screen adds a live display and on-screen settings to the unit.
RadGreen also offers an ELF (50 Hz) magnetic field monitoring unit. Let us know if this is relevant to your site.

Specifications
Tell us about your application, the frequencies you work with and how many locations you want to cover, and we will come back to you with the right configuration and the full specification.
Frequently asked questions
RadGreen RF units cover 100 MHz to 40 GHz and are band-selective, so each unit is set up for the part of the spectrum relevant to where it is installed. We can help you choose the right configuration for your application.
No, periodic calibration is not required, and the units are maintenance-free. Thresholds are set once for each installation.
Yes. The Local Visual and Voice unit gives visual and audible alerts on the device itself and needs no communication network, so it suits security-sensitive sites, including military and defence. An optional screen adds a live display and on-screen settings.
Yes. Connected indoor and outdoor units report to a central platform, which handles alerts, data logging and remote configuration across multiple locations from one system.
Each unit monitors the area around it, so placement matters. Typical positions are outside a chamber or shielded room, beside an ATE rack, or close to cable runs and loads carrying high RF power. We can advise on placement for your layout.
Yes. As well as the RF range, RadGreen offers an ELF (50 Hz) magnetic field monitoring unit. Get in touch if this is relevant to your site.
No. RadGreen is an alerting system. It monitors the RF environment continuously and alerts when levels rise above a set threshold, but it is not a substitute for calibrated measurement equipment such as a spectrum analyser, EMI receiver or field probe. It is designed to run alongside that equipment and cover the time between tests.