AC2000C: a complete IEC 61000-3-2 and IEC 61000-3-3 compliance test system
The AC2000C is a complete harmonics and flicker test system for products that have to demonstrate compliance with IEC 61000-3-2 and IEC 61000-3-3. It brings together a precision power analyser, a flicker impedance network and a programmable AC power source, so a full compliance test runs from one software package rather than a bench of separate instruments.
Harmonic and interharmonic currents are measured to IEC 61000-4-7, and voltage fluctuation and flicker to IEC 61000-4-15. Results are evaluated against the limits of IEC 61000-3-2, -3-3, -3-11 and -3-12, then archived and reported from the same software. The AC2000C sits alongside the rest of the Laplace EMC analyser range.

- Harmonic analysis up to the 500th order with voltage fluctuation and flicker measurement
- Single and three-phase configurations from 3 kVA to 90 kVA
- Flicker impedance networks from 16 A to 75 A (Arms)
- Automatic limit selection by equipment class, A to D
- Options for voltage dips, interruptions and power quality immunity testing
Why harmonics and flicker testing is required
Any mains-powered product sold in Europe has to limit the distortion it imposes on the supply. Switched-mode power supplies, LED drivers and motor controllers draw current in short, non-sinusoidal pulses rather than smoothly across the cycle. Multiply that across thousands of installed products on the same network and the result is measurable harmonic distortion, which reduces distribution efficiency and can affect other equipment sharing the supply.
IEC 61000-3-2 sets limits on the harmonic currents a product is allowed to draw. Limits differ across four equipment classes, and for Class C and Class D they depend on the product’s power, which is why the class and the measured power both have to be established before a test is meaningful.
IEC 61000-3-3 addresses the other half of the problem. When a product’s load changes, it causes a momentary voltage drop on the supply. If those changes repeat at the wrong rate, the result is visible flicker in lighting on the same circuit. The standard defines short-term and long-term flicker severity, Pst and Plt, along with the relative voltage change parameters dc, dmax and Tmax.
Both tests have to be made against the reference impedance defined in the standard rather than whatever the local supply happens to present. That is the function of the impedance network, and it is the part most often missing from an improvised test setup.
For equipment drawing more than 16 A per phase, IEC 61000-3-12 and IEC 61000-3-11 apply instead. These work on conditional connection rather than absolute limits, and testing is performed against a test impedance rather than the reference impedance.

Comprehensive
One system covers analysis, supply and impedance. Switching between harmonics and flicker modes can be manual or automatic, and configurations run from a 3 kVA single-phase source to a 90 kVA three-phase source.
Compliance
Harmonic current limits are preset by product category, Class A to Class D. Class C and D limits are matched to measured power, or the rated power can be entered by the operator.
Precision
All real-time processing runs on the DSP inside the analyser, so PC performance does not affect measurement accuracy. Basic accuracy is ±(0.03% reading + 0.05% range).
Convenient
Windows-based software handles configuration, display, archiving and compliance reports over RS232, LAN or USB. Tests can be non-timed, manually timed or automatically timed.
What the system includes
Power and harmonics analyser
A standalone analyser with one to five voltage and current measurement channels and up to four input modules of different specifications, so a single instrument can cover several measurement ranges.
Harmonic analysis runs to the 500th order in compliance with IEC 61000-4-7 Ed2.1, using a high-speed independent DSP. The maximum update rate is 10 ms, and auto-update tracks signals changing from 0.1 Hz, which matters when the product under test has a fluctuating load.
Alongside compliance measurement, the analyser functions as a mains power meter and inrush current meter, with tabular, waveform, trend and bar graph displays.
Flicker impedance network
Standard-compliant flicker testing requires the product to be measured against a defined impedance. The AC2000C series network covers 16 A (Arms) units for IEC 61000-3-3 up to 75 A (Arms) units for IEC 61000-3-11, switchable between Zref and Ztest.
Air-core inductors avoid saturation at high current, and forced air cooling minimises temperature drift under sustained load. The 16 A version has three independent outputs.
Three models are available: FL1P16L single-phase 16 A, FL3P16L three-phase 16 A and FL3P75L three-phase 75 A.
Programmable AC power source
Harmonics and flicker measurements are only as good as the supply behind them. The L78 series source provides a clean, programmable supply across single-phase, three-phase and reversed phase operation, from 3 kVA to 90 kVA.

System configurations
Each standard configuration includes the harmonics analyser and flicker meter with reference impedance, matched to a power source.
| Model | Phase | Power source |
|---|---|---|
| AC2000C-03-CTS | Single-phase | 3 kVA |
| AC2000C-05-CTS | Single-phase | 5 kVA |
| AC2000C-303-CTS | Three-phase | 30 kVA |
| AC2000C-603-CTS | Three-phase | 60 kVA |
| AC2000C-903-CTS | Three-phase | 90 kVA |
Options
The system can be extended beyond harmonics and flicker into power quality immunity testing, including IEC 61000-4-11 voltage dips and interruptions.
| Option | Covers |
|---|---|
| DIPS1P16 | IEC 61000-4-11 and -4-29 voltage dips and interruptions, single-phase, including tapped transformer |
| DIPS3P30 | IEC 61000-4-11 and -4-34, three-phase, 32 A |
| DIPS3P75 | IEC 61000-4-11 and -4-34, three-phase, 75 A |
| DIPS3P200 | IEC 61000-4-11 and -4-34, three-phase, 200 A |
| 413 | IEC 61000-4-13 harmonics and interharmonics immunity, also supporting -4-14, -4-17 and -4-28 |
Key specifications
| Measurement channels | 1 to 5 (voltage and current), up to 4 input modules |
|---|---|
| Voltage range | 1000 V (±3000 V pk) |
| Current range | 2 mA to 5 A internal; 60 A and 200 A via CT |
| Frequency range | DC to 500 kHz |
| Basic accuracy | ±(0.03% reading + 0.05% range) |
| Update rate | Max. 10 ms, auto-update tracks signals from 0.1 Hz |
| Harmonic order | Up to 500th, compliant with IEC 61000-4-7 Ed2.1 |
| FFT window | Continuous 4, 10, 12 or 16 cycles |
| Flicker parameters | dmax, dc, t(max), Pst, Plt |
| Flicker accuracy | Better than 5% (Pst range 0.7 to 10.0) |
| Supply frequency | 50 Hz (available range 43 to 67 Hz) |
| Impedance accuracy | Within ±3% |
| Interfaces | LAN x 1, RS-232 x 3, USB x 4, HDMI x 1 |
| Dimensions | 800 x 600 x 1860 mm (D x W x H) |
Full specifications, including the flicker impedance test requirement table and power source ratings, are in the datasheet.
Frequently asked questions
Which standards does the AC2000C test to?
Measurement is to IEC 61000-4-7 for harmonics and interharmonics and IEC 61000-4-15 for voltage fluctuation and flicker. Results are evaluated against the limits in IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11 and IEC 61000-3-12. Options extend the system to IEC 61000-4-11, -4-13, -4-14, -4-17, -4-28, -4-29 and -4-34. You can read more about what each of these covers on our EMC standards page.
What is the difference between IEC 61000-3-2 and IEC 61000-3-12?
IEC 61000-3-2 applies to equipment drawing up to and including 16 A per phase and sets absolute harmonic current limits by equipment class. IEC 61000-3-12 applies above 16 A and up to 75 A per phase, and works on conditional connection, where compliance depends on the short-circuit ratio at the point of connection.
Do I need a flicker impedance network?
Yes, for any valid IEC 61000-3-3 or IEC 61000-3-11 flicker measurement. The standards define the impedance the product must be tested against, and a real mains supply will not present that impedance. Without the network you are measuring the behaviour of your building’s wiring as much as the product. The reference impedance is included with every AC2000C configuration.
Can it test products drawing more than 16 A?
Yes. The FL3P75L three-phase network covers up to 75 A (Arms) for IEC 61000-3-11 and IEC 61000-3-12 testing, switchable between Zref and Ztest, with customised Ztest available for Zmax conditions.
Does it handle lighting products under 25 W?
Yes. The software supports all three measurement methods permitted for lighting rated from 5 W to 25 W: the table method, the waveform method and the THD method. They can be applied individually or in any combination, in line with the current requirements of IEC 61000-3-2.
Can I test a product under a fluctuating load?
Yes. The analyser has a maximum update rate of 10 ms and an auto-update mode that tracks signals changing from 0.1 Hz, adjusting the data update rate to the input frequency. Before a formal compliance run, the repeatability of the product’s current can be evaluated, which is worth doing on any product whose current is not stable.
How are results reported?
The Windows software produces compliance test reports covering supply voltage parameters, per-order harmonic currents against limits with pass or fail judgement, and voltage fluctuation values with Pst classes and Plt. Full measurement data can be played back after the test.
What happened to the AC2000A?
The AC2000A has been discontinued. The AC2000C replaces it.
Enquire about the AC2000C
If you would like to discuss which configuration suits your product, or you are not sure which standards apply to it, get in touch and we will talk it through.